Wärtsilä 20 Lubricating Oil Filter Element

Sources:
  • Wärtsilä Technical Bulletin, Version 0011 — "Round type filter candle for automatic lubricating oil filters on Wärtsilä 20 engines" (Engine Section, Lubrication oil system), betrifft W20 und Auxpac20 Motoren mit Built-on Automatic Lubrication Oil Filter Typ BOLL & KIRCH 6.46 DN50 / 6.46 DN65 / 6.48 DN65

The Wärtsilä 20 Lubricating Oil Filter Element is a filter element used in built-on automatic lubricating oil filters on Wärtsilä 20 and Auxpac 20 engines. The element is identified as part number 471063 and is described by Wärtsilä as a filter element / filter candle with a round cross-section.

The element is used with automatic lubricating oil filters of type BOLL & KIRCH 6.46 DN50, 6.46 DN65 or 6.48 DN65. The maximum service life specified by Wärtsilä is 8000 operating hours or two years in service.

 

 

Technical Data

  • OEM Number: 471063
  • MPN: —
  • Filter Media: —
  • Micron Rating: —
  • Engine Family: Wärtsilä 20
  • Filter Type: Automatic Oil Filter

Compatible Engines

Application Notes

Used in built-on automatic lubricating oil filters on Wärtsilä 20 and Auxpac 20 engines. The filter element 471063 is specified for automatic lubricating oil filters of type BOLL & KIRCH 6.46 DN50, 6.46 DN65 or 6.48 DN65. The filter candle has a round cross-section.

Additional Notes

The filter candles have a maximum service life of 8000 operating hours or two years in service, whichever occurs first. The candles should always be replaced when a differential-pressure alarm occurs and immediately if a candle is found to be defective.

The Wärtsilä 20 Lubricating Oil Filter Element (part no. 471063) is the filter candle used in the built-on automatic lubricating oil filter (471056) fitted to Wärtsilä 20 and Auxpac 20 engines. It is designed with a round cross-section and is used with automatic lubricating oil filters of type BOLL & KIRCH 6.46 DN50, 6.46 DN65 or 6.48 DN65.

According to the manufacturer’s technical bulletin (version 0011), the filter candle has a maximum service life of 8000 operating hours or two years in service, whichever occurs first. The candle must be replaced whenever a differential-pressure alarm occurs, and immediately if it is found to be defective.