Wärtsilä 50DF Safety Filter (HFO)

Sources:
  • Wärtsilä 50DF Product Guide (a17, 4 November 2016) – Section 6, Fuel System, Safety filter (1F03) Page: 6-42

The Wärtsilä 50DF Safety Filter (HFO), designated 1F03 in Wärtsilä documentation, is a full-flow duplex-type filter with steel net in the fuel oil system of Wärtsilä 50DF engines. The filter should be equipped with a heating jacket and installed as close as possible to the engine.

Wärtsilä documentation specifies a filter fineness of 37 µm (absolute mesh size) and a design pressure of 1.6 MPa (16 bar) for this filter.

Technical Data

  • OEM Number: —
  • MPN: —
  • Filter Media: —
  • Micron Rating: 37 µm
  • Engine Family: Wärtsilä 50DF
  • Filter Type: Duplex Fuel Filter, Safety Filter

Compatible Engines

Application Notes

Used in the fuel oil system of Wärtsilä 50DF engines and identified as Safety filter (1F03) in Wärtsilä documentation. The filter is a full-flow duplex type with steel net, specified with a fineness of 37 µm (absolute mesh size) and a design pressure of 1.6 MPa (16 bar). Wärtsilä documentation states that the filter should be equipped with a heating jacket and installed as close as possible to the engine

Additional Notes

Wärtsilä documentation specifies the following design data for the Safety filter (1F03): design temperature 150 °C, design flow equal to circulation pump capacity, design pressure 1.6 MPa (16 bar), and a filter fineness of 37 µm (absolute mesh size). Maximum permitted pressure drops at 14 cSt are specified as 20 kPa (0.2 bar) for a clean filter and 80 kPa (0.8 bar) at alarm. Exact dimensions and OEM part numbers should be confirmed against the applicable Wärtsilä documentation and the installed component before ordering or replacement.

The Wärtsilä 50DF Safety Filter (1F03) is a full-flow duplex filter with steel net used in the fuel oil system of Wärtsilä 50DF engines. Wärtsilä documentation states that the filter should be equipped with a heating jacket and installed as close as possible to the engine.

Wärtsilä documentation specifies the following design data for 1F03: design pressure 1.6 MPa (16 bar), design temperature 150 °C, design flow equal to circulation pump capacity, and a filter fineness of 37 µm (absolute mesh size). Maximum permitted pressure drops at 14 cSt are specified as 20 kPa (0.2 bar) for a clean filter and 80 kPa (0.8 bar) at alarm.